Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mater Horiz ; 11(3): 803-812, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38010915

RESUMO

In this work, we demonstrate, for the first time, that coupling together the pyroelectric effect, the photovoltaic effect and the plasmonic effect is a novel method to significantly enhance the performance of self-powered photodetectors in the visible region. Photodetectors based on tri-layered heterojunction of n-Si/p-SnO/n-ZnO through the inclusion of silver (Ag) nanoparticles (NPs) at the SnO/ZnO interface were fabricated. The photo-response of the device, with excitation from a chopped 650 nm wavelength laser, was carefully investigated, and it was shown that the photodetector performance is enhanced the most with the inclusion of spheroidal Ag NPs with ∼70 nm diameter. The Al/Si/SnO/Ag NPs/ZnO/ITO device exhibited an optimum responsivity, detectivity and sensitivity of 210.2 mA W-1, 5.47 × 109 Jones and 15.0 × 104, respectively, together with a rise and fall time of 2.3 and 51.3 µs, respectively, at a laser power density of 317 mW cm-2 and at a chopper frequency of 10 Hz. The present photodetectors are more than twice as responsive as the current best-performing ZnO-based pyro-phototronic photodetectors and they also exhibit other competitive features, such as detectivity, and fall and rise times. Therefore, by exploiting the plasmonic effect of the Ag NPs together with the pyroelectric effect in a ZnO film, and the photovoltaic effect at a Si/SnO junction, all in a single device, photodetectors were developed with state-of-the-art performance for the visible region.

2.
Small ; 19(32): e2300607, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37086105

RESUMO

Self-powered photodetectors (PDs) have been recognized as one of the developing trends of next-generation optoelectronic devices. Herein, it is shown that by introducing a thin layer of SnO film between the Si substrate and the ZnO film, the self-powered photodetector Al/Si/SnO/ZnO/ITO exhibits a stable and uniform violet sensing ability with high photoresponsivity and fast response. The SnO layer introduces a built-in electrostatic field to highly enhance the photocurrent by over 1000%. By analyzing energy diagrams of the p-n junction, the underlying physical mechanism of the self-powered violet PDs is carefully illustrated. A high photo-responsivity (R) of 93 mA W-1 accompanied by a detectivity (D*) of 3.1 × 1010 Jones are observed under self-driven conditions, when the device is exposed to 405 nm excitation laser wavelength, with a laser power density of 36 mW cm-2 and at a chopper frequency of 400 Hz. The Si/SnO/ZnO/ITO device shows an enhancement of 3067% in responsivity when compared to the Al/Si/ZnO/ITO. The photodetector holds an ultra-fast response of ≈ 2 µs, which is among the best self-powered photodetectors reported in the literature based on ZnO.

3.
Adv Sci (Weinh) ; 10(15): e2207390, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36950722

RESUMO

A new approach for the stabilization of the ferroelectric orthorhombic ZrO2 films is demonstrated through nanosecond laser annealing (NLA) of as-deposited Si/SiOx /W(14 nm)/ZrO2 (8 nm)/W(22 nm), grown by ion beam sputtering at low temperatures. The NLA process optimization is guided by COMSOL multiphysics simulations. The films annealed under the optimized conditions reveal the presence of the orthorhombic phase, as confirmed by X-ray diffraction, electron backscatter diffraction, and transmission electron microscopy. Macroscopic polarization-electric field hysteresis loops show ferroelectric behavior, with saturation polarization of 12.8 µC cm-2 , remnant polarization of 12.7 µC cm-2 and coercive field of 1.2 MV cm-1 . The films exhibit a wake-up effect that is attributed to the migration of point defects, such as oxygen vacancies, and/or a transition from nonferroelectric (monoclinic and tetragonal phase) to the ferroelectric orthorhombic phase. The capacitors demonstrate a stable polarization with an endurance of 6.0 × 105 cycles, demonstrating the potential of the NLA process for the fabrication of ferroelectric memory devices with high polarization, low coercive field, and high cycling stability.

4.
BMC Pulm Med ; 13: 13, 2013 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-23497046

RESUMO

BACKGROUND: Reduced plasma nitrate (NO(x)) levels and increased urinary norepinephrine (U-NE) levels have been described in severe obstructive sleep apnea (OSA), and are reverted by continuous positive airway pressure (CPAP). The effect of CPAP on these biomarkers in mild-moderate OSA is not well understood. The aim of this study was to compare NO(x) and U-NE levels and blood pressure (BP) between male patients with mild-moderate and severe OSA and determine the impact of 1 month of CPAP therapy on these parameters. METHODS: We undertook a prospective study of 67 consecutive OSA patients (36 mild-moderate, 31 severe). Measurements of plasma NO(x) at 11 pm, 4 am and 7 am, 24-h U-NE and ambulatory BP were obtained at baseline and after 1 month of CPAP. RESULTS: At baseline, NO(x) levels showed a significant decrease during the night in both groups (p < 0.001). U-NE level and BP were significantly higher in the severe OSA group. After 1 month of CPAP, there was a significant increase in NO(x) levels and a reduction in U-NE level and BP only in patients with severe OSA. CONCLUSIONS: One month of CPAP results in significant improvements in NO(x) levels, 24-h U-NE level and BP in patients with severe OSA, but not in patients with mild-moderate OSA. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01769807.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Nitratos/sangue , Norepinefrina/urina , Síndromes da Apneia do Sono/metabolismo , Síndromes da Apneia do Sono/terapia , Adulto , Biomarcadores/sangue , Biomarcadores/urina , Monitorização Ambulatorial da Pressão Arterial , Humanos , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Polissonografia , Estudos Prospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...